Precautions for installation and use of electromagnetic pulse valve

1. After unpacking, check whether the operation manual, factory certificate and packing list are complete. Then check whether the product name and model are consistent with the list, and check whether the nameplate is consistent with the purchase order. If there is any defect or discrepancy, contact the manufacturer in time to try to solve it

2. When the solenoid valve fails, in order to isolate in time and facilitate maintenance, it is recommended to install a bypass (bypass) device

3. Before installation, please thoroughly purge the air bag and pipeline to avoid foreign matters damaging the diaphragm and causing solenoid valve failure

4. The best installation method of solenoid valve is vertical to the horizontal pipe and the coil is upward. When conditions do not allow, and it should be more safe to keep pace with the times, it is allowed not to adjust the equipment casually ± 30 ° tilt. Otherwise, normal use cannot be guaranteed

5. 4. Conference cost: 2000 yuan/person. In order to prevent the explosion and other accidents caused by electric sparks in dangerous environments, explosion-proof solenoid valves should be used

6. The arrow on the solenoid valve body should be consistent with the flow direction of the medium